internal walls and floors of buildings. The guidance relating to this part of the regulations is contained in Section 5 of the Approved Document. In a typical domestic situation stud walls around bedrooms and bathrooms need 75mm studwork with either two layers of plasterboard on each side, and 25mm of sound insulation incorporated within the wall. covered with floor boarding which achieves 15kg/m2 (i.e. 21mm tongued and grooved boarding) and this should cover the entire floor and remaining ceiling joists to the eaves. This boarding should also be provided with screw fixings. 100mm mineral wool insulation should be provided between the new floor joists, insulation to be a minimum of 10kg/m2 (see diagram below). minimum mass per unit area 10kg/ m2; minimum distance between linings of 75mm, or metal frame with a minimum distance between linings of 45mm; mineral wool batts or quilt (minimum thickness 25mm, minimum density 10kgg/m3) which may be wire reinforced, suspended in the cavity; of plasterboard, each sheet of minimum mass per unit area 10kg/ m2; minimum distance between linings of 75mm, or metal frame with a minimum distance between linings of 45mm; area 15kg/2; area 10kg/m2, fixed using any normal fixing method; · an absorbant layer of mineral wool (minimum thickness 100mm, minimum density 10kg/m3) laid in the cavity should be made to improve their sound resistance. |